I live in an area where radon issues are common. A (nonsmoking!) friend died of lung cancer and radon was the probable cause. So it is something we should all take seriously. The building code here requires radon mitigation in all new houses, and mine is new enough to have it. But I wanted to check whether it is working, so I got this Ecosense EB1000 Ecoblu to test it. Set it up in my basement and the numbers are high, between 5 and 6! Yikes!
I read the review from Brian B, who says it reads inaccurately high. So I tested this myself by moving the Ecoblu outside. I left it outside for four days and never saw it read above 0.3. Brought it back inside and it quickly shot back up over 5. Based on my comparison, outside to in, I do NOT think it reads inaccurately high. I think I have an issue here.
My existing radon mitigation is a passive system, just a pipe from the sump crock out through the roof. The next step here is to add a fan. I have the radon mitigation people coming out to do that in a couple weeks. I will have them do a professional test as well, just to confirm these numbers. I will update this review to report how it turns out, but it’s going to take a while to find out.
All my friends want to borrow it now. I am encouraging them to get their own!
Edited Nov 17 2022:
I promised to update this review to let folks know how this turned out.
It took a couple weeks to get the radon mitigation company out here. During this time we saw numbers as high as 14 on our Ecoblu. Yikes!
When the pros finally got here, they could not upgrade our system with a fan, due to how the pipe was routed. They wanted us to get someone else to come out and reroute the pipe, first. They also diagnosed another issue with our passive system. The radon pipe comes out of the sump, which is supposed to be otherwise sealed. But we also had several vented pipes going into that same sump crock, which were allowing radon to seep in.
Ultimately, my husband did the fix himself. He rerouted the radon pipe, added the fan, and changed the other pipes to not vent through the sump.
Within a few hours of these changes, our Ecoblu reading had dropped below 1 picocurie. It’s been several days now and it continues to hover between 0.5 and 0.9. I am so relieved!